AirChek TOUCH (5 to 5000 ml/min)

The SKC AirChek TOUCH air sampling pump is the first personal sample pump with color touch screen navigation. Ultra-quiet and tough AirChek TOUCH provides extended flows from 5 to 5000 ml/min and high back pressure compensation for all your IH applications. Programming continuous, timed, and intermittent sampling is easy -- no instruction manual needed. A powerful Li-Ion battery provides long run times. Charging, calibration, and PC communication are made easy with all-in-one cradles. Use AirChek TOUCH with DataTrac Pro Software for time-saving pump and data management.

The AirChek TOUCH air sampling pump is UL Listed for intrinsic safety.


  • Extended flows from 5 to 5000 ml/min
  • Color touch screen navigation, easy programming
  • Continuous, timed, and intermittent sampling
  • Hands-free CalChek® calibration
  • High back pressure compensation
  • Powerful Li-Ion battery for long run times
  • Corrects flow for changes in temperature and atmospheric pressure
  • Screen protection and security
  • Ultra quiet

Universal Pumps [Personal or Area Sampling]

The result of extensive research and development, the PCXR8 is a constant flow air sampling pump suited for a broad range of applications. With an operating range of 1000 to 5000 ml/min (low flow applications of 5 to 500 ml/min require an optional adjustable low flow holder), this battery-operated air sampling pump is ideal for industrial hygiene studies as well as environmental testing. 


The PCXR8 on-board computer makes operation easy and permits unattended sampling for periods up to 7 days. In addition, the PCXR8 offers:
  • Multiple-tube sampling capability
  • Compensation with high back pressure
  • Quiet-running package
  • Wide range of flow rates
  • Energy efficiency
  • Programmable timing


Pocket Pump TOUCH (20 to 500 ml/min)

The new Pocket Pump TOUCH personal air sample pump provides low flows from 20 to 500 ml/min for gas and vapor sampling. Pocket Pump TOUCH features touch screen operation that feels like your cell phone, Bluetooth connectivity to PC and DataTrac Pro Software, powerful Li-Ion battery for 20-hour run times, exhaust port for bag sampling, USB charging, and more in a miniature pump that fits in your pocket. Pocket Pump TOUCH is UL Listed for intrinsic safety.


  • Easy touch screen operation and calibration
  • Constant flows from 20 to 500 ml/min
  • Bluetooth wireless connectivity with PC and DataTrac Pro Software
  • Large backlit display
  • Powerful Li-Ion battery for > 20-hour run times
  • Only 8.3 ounces (235 grams)
  • Multi-tube sampling — save time and use fewer pumps
  • Automatic flow fault and restart
  • Secure screen during sampling with auto-lock feature


AirChek 52

The full range of flow rates is available in one lightweight, low-cost, heavy-duty sampler:

The AirChek 52 Air Sampling Pump becomes a fully versatile sampler when combined with the low flow Constant Pressure Controller (CPC) (Cat. No. 226-26-CPC) accessory. The CPC permits sampling in the 5 to 500 ml/min range.

Simple to use, the CPC fits into the sampling train tubing allowing the pump to operate in a constant pressure mode. In the low flow mode, an adjustable low flow tube holder can be used to collect up to four tube samples simultaneously and at different flow rates. The flow rate at each intake of the adjustable low flow tube holders can be set from 5 to 500 ml/min (dependant on back pressure). Multiple-tube sampling reduces time in the field and uses fewer pumps.

Lightweight, Durable:

Measuring approximately 5 x 3 x 1.75 inches (12.7 x 7.6 x 4.4 cm) and weighing only 20 ounces (567 grams), the small size, lightweight, and durable construction allows the AirChek 52 to withstand the rigors of on-worker use time and time again. Rechargeable NiMH or NiCad batteries provide a reliable power source which can be restored overnight. The AirChek 52 is the lightweight, inexpensive workhorse pump designed for rugged and repeated use

  • Flow range of 1000 to 3000 ml/min
  • Constant flow compensation
  • For both high and low flow applications
  • Minimum controls for easy operation
  • RFI/EMI shielded and UL Listed for intrinsic safety
  • Highly accurate display
  • Low flow sampling capabilities
  • Multiple-tube sampling capabilities
  • Full shift run times
  • Small, compact and lightweight
  • Simple design, smooth surface
  • Built-in pulsation dampener
  • Built-in replaceable particulate trap
  • Quiet operation
  • Replacement parts in preassembled modules
  • Fully encapsulated electronics for corrosion resistance